Just unboxed my new radiator, wondering which fittings to order ? I just wanted to share this, because for me as a watercooling PC guy, this is hilarious. Wondering how much LTT fans could be mounted on that thing ?
-
I7 8700k High temps with water cooling
CaSsE replied to sam1441's topic in Custom Loop and Exotic Cooling
Just bought an 8700k myself and I find everyone using auto voltages is complaining about bad TIM or "my CPU runs to hot". I tried it the good old way: AUTO voltages and my aimed core speed-> look what the board uses and drop it use lowered but fixed voltages -> try reducing it as much as possible So now my CPU is on 48 all cores and not even touching 60°C after hours of gaming. After 1 hour P95 its around 65°C sometimes touching 70°C (22° ambient). Proves for me: nothing has changed till 5 years ago, AUTO is always easy but more wearing on your hardware. -
that´s normally the inlet to prevent splashing.
-
with this setup you shouldn´t have any flow in the GPU, or am I wrong? I was wrong it´s just parallel with uneven flow or smt...time to sleep.
-
Ordering directly from Alphacool
CaSsE replied to colbymchenry's topic in Custom Loop and Exotic Cooling
DHL is superior. Alphacool products are awesome, but the onsite shop I don´t know anything about. -
We all love Giveaways!!!
-
I like the Kuhler the most even if I could use all of the stuff anyways :-D
-
New processor and motherboard no video output from graphics card
CaSsE replied to yudothat2me's topic in Troubleshooting
Changed Initial Display to pci-e ? -
How much difference does RAID 0 actually make for hard drives?
CaSsE replied to Cs342's topic in Storage Devices
http://www.hardwaresecrets.com/article/Does-RAID0-Really-Increase-Disk-Performance/394/6 -
works fine
-
From the album: Screenshots
-
how to thoroughly clean dust from inside fins on radiator
CaSsE replied to ukaussi's topic in Custom Loop and Exotic Cooling
dishwasher works fine for radiators. just make sure you probably dry them. otherwise you´ll get rust inside the sidecovers. -
you wouldnt have any flow in both cards because the water would go straight from top to bottom. | i | | | | i | | i |
-
Is watercooling worth it to you?
CaSsE replied to Air tree's topic in Custom Loop and Exotic Cooling
It´s a hobby like pimping a car...not usefull but makes you happy ;-) -
Why aren't servers/supercomputers water cooled?
CaSsE replied to BoggyB's topic in Custom Loop and Exotic Cooling
There are "Watercooled" supercomputers, or at least 1 in Germany, named SuperMUC. http://www.lrz.de/services/compute/supermuc/ http://www.lrz.de/presse/ereignisse/2010-12-13_supermuc-vertrag/warmwasserkuehlung/- 26 replies
-
Most, if not all, Pumps work in "pull"...so they pull their material (water, concrete, doesn´t matter) from a feeding source. It´s urgent for the first filling, after that you got a "nearly" closed loop thats not effected by this "pull" principle at all.
-
Watercooling is amazing!
-
[Build Log] RGD - Custom Built Surround Monitor Stand
CaSsE replied to Complx's topic in Cases and Mods
This is really a nice job. I´m pretty jealous! -
Using 4 pin fans on 3 pin connections is something i havent tried and heard of yet. USB is just needed for installation, after that you can unplug the USB and it works on its own. (sure, you cant monitor anything on desktop then) You are controlling each fan header. So if you connect 2.3 or 4 fans on 1 header all will run the same speed.
-
Alphacool Heatmaster ( I or II ) http://www.alphacool.com/product_info.php/info/p999_Alphacool-Heatmaster-II.html?language=en just use splitter cables to run multiple fans off one port.
-
XSPC worked fine for me in 2 builds with single DDC Dual Bay. http://wvw.schottenland.de/preisvergleich/Xspc-Dual-Bay-Ausgleichsbehaelter-fuer-5-p21686019 no vibration at all. "2 Rads+ CF 6950+ CPU+ 3 MB blocks= 1 DDC 1T http://www.aquatuning.de/product_info.php/info/p5080_Laing-DDC-Pumpe-12V-DDC-1T-Plus.html